Restore required indicates that the event programmed requires a restoring event before resetting the Zone status back to normal.
- To use the timeout feature, the customer record must have the checkbox "Generate Restore Overdues" enabled. This timeout tells the signal handler to generate a new alarm event, "Restore Overdue," if the applicable restoring event does not arrive within the prescribed time period.
- The Restore Command has two choices: Restore just restores the one event matching the zone, and Restore (Category) restores all zones within the selected event category.
PROGRAMMING RESTORE REQUIRED
- Enter a new programming line within the customer record.
- Tab to the Commands Column, click the ellipsis button, locate the RestReq command, and double-click it to move it from the left-hand column to the right-hand column (see below).
- Select the restoring Event.
- Select the restoring Zone.
- If applicable, enter the timeout.
- Select the applicable Restored option.
- If applicable, select the Repeat checkbox.
- Click OK.
- If the restoring event is not within the same event category (such as Fire or Burglary), enter a new line of programming for the restoring event, then tab over to the Commands column and click the ellipsis button.
- Locate and move the Restore command from the left-hand column to the right-hand column.
- Click OK.
- Save the Record.