The RestRq(Event,Zone,Timeout,Restored,Repeat) command defines the requirement of a restore for the event and, when applicable, zone. Used often for Fire events on Commercial accounts.

Command Parameters
- Event - Determines which event restores the alarm. Using a asterisk (*) looks for any restoring event in the SAME event category.
- Zone - Defines which zone restores the alarm. Using an asterisk (*) looks for any zone with the restoring event.
- Timeout - Length of time, in minutes, to wait for the restoring event to arrive.
- Restored - Determines if ONLY the alarm zone or all zones must be restored in order to restore the event.
- Repeat - When enabled, this determines if the Restore Overdue generates, should the timeout reset and repeat the Restore Overdue event.
Please note - The Timeout may be configured at the global event code level but will not be enabled unless and until the account that needs it has the "Generate Restore Overdue" checkbox enabled.
Restored - If set to restrict closure until it or all zones are restored will not allow an operator to close the alarm until the alarm restore is received. If necessary, you may send a Manual signal to restore the event. If it is flagged for all zones to be restored in order to close the alarm, you will need to send restoring events for all pending zones or remove the zone statuses from the Areas & Zones form.