Transmitter Programming Commands

Transmitter Programming Commands used on Customers and Transmitter Types.

Articles

Transmitter Programming Commands
Transmitter Programming Commands are available in many locations within the Manitou system.  Any place where there are events or translations to events have Transmitter Programming Commands. Event Codes   Transmitter Type Programmi...
Audio
The Audio command signifies the signal contains audio capabilities.  This requires that the Transmitter Type in use on the account's transmitter contains the "Audio Capable" option. Command Parameters Type  - Yes or Listen...
CanCancel
The CanCancel programming command Enables an event may be canceled by the Manitou Signal Handler when a canceling event arrives within the timeout period.  This does not function without the Cancel() option on the canceling event code . ...
Cancel
The Cancel command enables a canceling event with the power to cancel an alarm event.   Not every event that may be used as a cancel will have in its event code the capacity to cancel an alarm.  Therefore, it is important to apply the cancel event t...
CanCancel Programming and Cancel Commands
Manitou, and the Manitou Web client, offers the ability to apply CanCancel Transmitter Programming to Event Code, Transmitter, and Customer programming to hold an event in “pre-alarm” state for a prescribed period of time to allow for the restoring/...
Confirmed
The Confirmed command allows the Signal Handler to flag the event as a Confirmed alarm when verified by details noted in the command.   Command Parameters ID  - Groups the Confirmed commands together.  Using an asterisk (*) f...
Dual
The Dual command  pairs signals together when two signals are required from the panel.  When the second signal doesn't arrive the system generates a "missing dual signal" alarm.   Command Parameters ID  - Groups the signals t...
EntryExit (EntryType)
The Entry Exit Delay command allows delivery delay of alarms based on Entry or Exit into the property.  This requires an Open/Close schedule and mapping of the zones included in the Entry and/or Exit delay.  This also assigns a monitoring service ...
GPS Programming Commands
The GPS related commands are: GPSAlarm, GPSEvent, and GPSLoc.  Which define the status and events related to events that signal with GPS (Global Positioning System) coordinates.  GPSAlarm identifies the GPS location event(s). This sets ...
IfClosed (Event, Alarm)
The IfClosed command determines based on the  open  or  closed  status of the area receiving the event, what event to deliver to operators.   Command Parameters Event - Defines what new event code to provide if the event arr...
IfOpen (Event, Alarm)
The  IfOpen  command determines based on the  open  or closed status of the area receiving the event, what event to deliver to operators.   Command Parameters Event  - Defines what new event code to provide if the event arrives...
InSched (Sched No., Event, Alarm)
The InSched command changes the event code delivered to the customer record based on the arrival of the event within the defined Programming General Schedule information.  This requires the customer contains a Programming General schedule ...
InTest (Event,Alarm)
The InTest  command defines an override event code delivered to the account when the system is On Test, and if the event delivers as an alarm. Command Parameters Event - Names the event code to override the event code receive...
NotifyMe Programming Commands
NotifyMe is an available efficiency service available to allow automated notifications and communications through an app.  This feature is licensed for the monitoring company and may be applied, individually on Dealers. NotifyMe The Notif...
Pri (Priority)
The Pri() command sets an override event priority for the event. Command Parameters Priority - The numeric value of the override priority.  (1-99) ...
PSAPLkup(Service Type)
The  PSAPLkup(Service Type) command determines what service to use to look up the appropriate PSAP (Public Safety Answering Point) based on the alarm.  Generally used in conjunction with GPS services. This command requires a service purchase a...
ResetTimeout(Event)
The  ResetTimeout(Event)  command is used in conjunction with CanCancel , Confirmed, and NotifyMe and allows reset timeout capability to restart the timeout period. Command Parameters Event - Specifies the event code that...
RestCat (EvCat)
The RestCat(EvCat) flags events with the power to restore unrestored events based on the Event Category.  This is often used where a restoring event may not be zone specific. Command Parameters Category - This defines which ...
Restore ()
The Restore() command provides the event with Restore capabilities.  Not every event code may contain the restore parameter, this command applies restore capacity to an event.     This command does not contain any parameters. ...
RestRq (Event, Zone, Timeout)
The  RestRq(Event,Zone,Timeout,Restored,Repeat)  command defines the requirement of a restore for the event and, when applicable, zone.  Used often for Fire events on Commercial accounts.  Command Parameters Event  - Determines...
Silent()
The Silent() command flags the event with this command as delivering silently from the monitored location. This command has no parameters to set. ...
Suspend (Timeout, Hidden)
The  Suspend(Seconds,Unavailable)  command force suspends the alarm event upon receipt of the alarm for the number of seconds defined.  The Unavailable option, when set, prevents operators from directly pulling the alarm from the alarm queue until t...
TempClose (Window)
The TempClose(Window) command sets a Must Close time following the Open event based on the Window time period of time, set in minutes, defined.   This requires monitored Open/Close service on the customer record. Command Parame...
Tour(ID,Sequence,Timeout)
The  Tour(ID,Sequence,Timeout)  command defines which events, zones, and timeouts that define a Guard Tour at the monitored location.  This is individually added to each zone involved in the guard tour.  This triggers a service when created. ...
TwoTrip (ID)
The TwoTrip(ID) command expects two events before generating an alarm to an operator.  The Two Trip timeout is managed globally within the Manitou Options. Command Parameters ID - Links the zones or events that particip...
User(ID, Override)
The UserID(ID,Override) command applies the defined User ID to the event.  Override determines if the event contains a User ID, if this User ID should override the one received. Command Parameters ID - Sets the numeric value...
Video()
The Video() command determines if the event and, when applicable, zone links to video technology.  This requires a Transmitter Type with the Video Capable option selected. This command does not have any parameters to set. ...